Intercambiador de calor de tubo corrugado formado por dos tubos concéntricos. Especialmente recomendable para el tratamiento de fluidos particulados o que contengan fibras o partículas en su seno. Perfectamente adaptable a Applicationsde toda naturaleza (industriales, medio-ambiente, higiénicas, etc.).

 
     
 
 
Applications

XTube® Tripletube heat exchangers are very suitable for the following applications:

  • Heating and cooling fluids of average and high viscosity, even including for small fibres and particles.
  • Heating and cooling of tomato concentrate.
  • Heating and cooling banana paste.
  • High temperature and pressure applications.
 
Materials of construction

All product wetted components (interior tube and bends etc.) are manufactured from AISI 316L stainless steel but for more aggressive fluids a range of Duplex stainless steels are also available.

The service side components are normally made from AISI 304 stainless steel but AISI 316L and Duplex steels may be used when required.

Areas not in contact with the working fluids are normally constructed from AISI 304 stainless steel.

Silicone rubber is used for the O ring seals and connection gaskets or seals but a wide range of alternative elastomers are available when specific applications require them.

Alternative materials can be offered for all wetted components on application.

 
Connections

To allow a rapid and flexible installation and easy inspection of the units the XTUBE® Tripletube heat exchangers use ISO standard ferrule/clamp connections. If the matching ferrules, clamps gaskets are required by the client for installation purposes these can be supplied on request to allow connection to the clients' pipe work system.

 

 

 
Design Conditions

The standard design conditions for the XTube® Tripletube heat exchangers are the following:

  • Minimum and maximum allowable working temperatures: -40°C / +180°C
  • Minimum and maximum allowable working pressures: 25 Bar(g)/Full vacuum

Higher pressures and temperatures are possible on request.

 
Standard dimensions

XTube® Tripletube heat exchangers can be delivered in various lengths, the standard dimensions being approximately 1500 mm, 2000 mm, 3000 mm and 6000 mm.

The exterior tube diameters used are as follows: Ø 88.9 mm, 104.0 mm, 114.3 mm, 129.0 mm, 141.3 mm and 168.3 mm. The tube thickness used will depend on the design conditions for each application.

The diameters of the interior tubes and their wall thickness will be chosen to meet the requirements of each application.